*23: For recommended cables and other information, contact the CC-Link Partner Association. Remote register RWw: 16-bit (word) unit data output from the master station to a slave station The status of link devices (RY, RWw) within the master station are transmitted to an external device connected to a slave station. *9: 16384 points and 2K bytes for the basic model QCPU and the MELSEC-QS Series Safety CPU. Please refer to the hub manufacturer's specifications. ⑦ The status of the slave station link devices (RX, RWr), and the local station link devices (RY, RWw) are stored in the master station link devices (RX, RWr) by link scan. Note that communication is made between the master station and the slave stations only. The status data of the control station link devices (LB, LW) are stored in the link devices (LB, LW) of each normal station. (1) Configure the entire network of CC-Link IE Field Network Basic in the master station. *15: Remote input RX: Bit data input from a slave station to the master station *2: Line and star types can also be mixed. *1: A hub is required to use the star type wiring. CC-Link IE compatible twisted-pair cable*23. Up to 20 hubs can be connected.

Link input LX: Data input from a station to the I/O master in the same block. CC-Link IE Field Network performance specifications, CC-Link IE Control Network performance specifications, CC-Link IE Field Network Basic performance specifications, 121 stations (1 master station. CC-Link IE Field Network Basic is an factory automation network using the standard Ethernet. Solutions include robots, automation platforms, sequence controllers, human-machine interfaces, variable frequency drives, servo amplifiers and motors, motion controllers, computer numerical control, PC-based CNC, linear servos, and industrial sewing machines, for a broad range of factory automation applications. As a result, all local stations possess the data of other slave stations, similar to the master station. When an input from a slave or local station is executed, the slave station link devices (RX, RWr) status and local station link devices (RY, RWw) status are stored in the master station link device (RX, RWr), along with other local station link devices (RY, RWw). For details on cyclic transmission, refer to the following. ⑥ In the local station, the status of the CPU module devices are stored in its own station link devices (RY, RWw) transmission area.
One-to-one communication is possible between the master and slave stations. Compliance statement Statement ... FX5U, MR-JE-A via Modbus, GX Works3. CC-Link IE field network Basic is also supported.

Remote output RY: Bit data output from the master station to a slave station Standard-equipped with an SD memory card slot, which is essential for functions such as logging and backup/restore. The status of link devices (RY, RWw) within the master station are transmitted to an external device connected to a slave station. ④ The status of the local station link devices (RX, RWr) are stored in the CPU module devices. The total number of allocated stations should not exceed the maximum number of slave stations. In the case of local stations, the status of the master station link devices (RY, RWw) is relayed to all local station link devices (RX, RWr) on the network. ② In the master station, the status of the CPU module devices are stored in the link devices (RY, RWw) by link *4: Number of link points allocated by the master station. CC-Link IE Field Network Basic compatible twisted-pair cable. *16: Number of link points allocated by the master station. For the details, please refer to the manual of the module used in the control station. *14: The maximum distance between stations depends on the actual hub used. If you want to know more or withdraw your consent to all or some of the cookies, please refer to the, Cpu module function block reference (44 pages), Analog control - intelligent function module (496 pages), Melsec iq-f series, ethernet communication (178 pages), Instructions, standard functions/function blocks (1112 pages), Manual will be automatically added to "My Manuals", Controller Mitsubishi Electric FX5U User Manual, Controller Mitsubishi Electric MELSEC iQ-F FX5U User Manual, Controller Mitsubishi Electric MELSEC iQ-F FX5 Reference Manual, Controller Mitsubishi Electric MELSEC iQ-F FX5 User Manual, Controller Mitsubishi Electric FX5 User Manual, Controller Mitsubishi Electric MELSEC iQ-F FX5 Programming Manual, Controller Mitsubishi Electric MELSEC iQ-F Series FX5 User Manual, Page 22: Chapter 3 Procedures Before Operation, Page 71: Details Of Buffer Memory Addresses. CC-Link IE Field Network Basic master module and the CC-Link IE Field Network Basic servo amplifier MR-JE-C. Motion control Specification: Part 1.
⑤ In the local station, devices of the CPU module turn ON. *10: 16384 points and 32K bytes for the basic model QCPU and the MELSEC-QS Series Safety CPU. *12: Maximum number of slave stations controlled by the master station, depending on the number of allocated slave stations. *11: To use the extended mode, all the stations must be compatible with the extended mode. *22: Value of remote register RWr + RWw (word).